Диссинхрония миокарда у больных с хронической сердечной недостаточностью: факторы, влияющие на развитие, особенности коррекции
https://doi.org/10.20514/2226-6704-2011-0-2-44-48
Abstract
The purpose of our research was to study features of development of dyssynchrony in patients with heart failure and different forms of ischemic heart disease, and also to estimate efficiency of cardiac resynchronization therapy. 125 patients with ischemic heart failure (including 17 patients, who were studied prior and within 1 week after biventricular pacing) were studied. Frequency of revealing dyssynchrony is connected with presence at patients an aberrant cardiac rhythm. After biventricular pacing we found significant positive dynamics of clinical and echocardiographic parameters in patients with heart failure.
About the Authors
А. И. ЧесниковаRussian Federation
кафедра внутренних болезней № 1
А. Ю. Фишман
Russian Federation
Центр кардиологии и сердечно-сосудистой хирургии, отдел УЗИ сердечно-сосудистой патологии
В. П. Терентьев
Russian Federation
кафедра внутренних болезней № 1
В. А. Сафроненко
Russian Federation
кафедра внутренних болезней № 1
References
1. Марцинкевич Г.И., Соколов А.А. Электромеханическая асинхронность и гетерогенность сердца при сердечной недостаточности // Сердечная недостаточность. 2005. Т. 6. № 3. С. 120–123.
2. Рыбакова М.К., Алехин М.Е., Митьков В.В. Практическое руководство по ультразвуковой диагностике. Эхокардиография. М.: Издательский дом Видар-М, 2008. 512 с.
3. Achilli A., Sassara M., Ficili S. et al. Long-term effectiveness of cardiac resynchronization therapy in patients with refractory heart failure and “narrow” QRS // J. Am. Coll. Cardiol. 2003. Vol. 42. № 12. Р. 2117–2124.
4. Bax J.J., Schinkel A.F.L., Boersma E. et al. Extensive left ventricular remodeling does not allow viable myocardium to improve in left ventricular ejection fraction after revascularization and is associated with worse longterm prognosis // Circulation. 2004. № 110 (II). Р. 118–122.
5. Calizio N.O., Pesce R., Valero E. et al. Which patients with congestive heart failure may benefit from biventricular pacing? // Pacing Clin. Electrophysiol. 2003. Vol. 26. № 1, 2. Р. 158–161.
6. Cazeau S., Bordachar P., Jauvert G. et al. Echocardiographic modeling of cardiac dyssynchrony before and during multisite stimulation: a prospective // Pacing Clin. Electrophysiol. 2003. Vol. 26. № 2. Р. 137–143.
7. Cleland J.G.F., Daubert J.C., Erdmann E. et al. The CARE-HF study (Cardiac Resynchronisation in Heart Failure study): rationale, design and end-points // Eur. J. Heart Fail. 2001. Vol. 3. № 4. Р. 481–489.
8. Koglek W., Brandl J., Oberbichler A. et al. Three-dimensional vectorcardiography to predict CRT-responder // Herzschrittmacherther Elektrophysiol. 2006. Vol. 17. № 1. Р. 28–36.
9. Peniscka M., Bartunek J., de Bruyne B. et al. Improvement of left ventricular function after cardiac resynchronization therapy is predicted by tissue Doppler imaging echocardiography // Circulation. 2004. Vol. 109. № 8. Р. 978–983.
10. Pitzalis M.V., Iacoviello M., Romito R. et al. Cardiac resynchronization therapy tailored by echocardiographic evaluation of ventricular asynchrony // J. Am. Coll. Cardiol. 2002. Vol. 40. № 9. Р. 1615–1622.
11. Yu C.M., Lin H., Fung W.H. et al. Comparison of acute changes in left ventricular volume, systolic and diastolic functions, and intraventricular synchronicity after biventricular and right ventricular pacing for heart failure // Am. Heart J. 2003. Vol. 145. № 5. Р. 846.
12. Yu C.M., Fung J., Lin H. et al. Predictor of left ventricular reverse remodeling after cardiac resynchronization therapy for heart failure secondary to idiopathic dilated or ischemic cardiomyopathy // Am. J. Cardiol. 2003. Vol. 91. № 6. Р. 684–688.
Review
For citations:
Чесникова А.И., Фишман А.Ю., Терентьев В.П., Сафроненко В.А. Диссинхрония миокарда у больных с хронической сердечной недостаточностью: факторы, влияющие на развитие, особенности коррекции. The Russian Archives of Internal Medicine. 2011;(2):44-48. (In Russ.) https://doi.org/10.20514/2226-6704-2011-0-2-44-48